CV 970AM & CV 970AA

 

Contronik Combination Gas Control CV 970AM

CV 970AM

Contronik Combination Gas Control CV 970AM

CV 970AM

Contronik Combination Gas Control CV 970AA

CV 970AA

Features:

- Include manual valve single operating

  knob (OFF, Pilot, ON) and fixed pressure

  regulator.

- Require the use of thermopile /

  thermocouple which heated by the pilot

  burner flame, provides the electric

  power to operate the combination gas

  control.

- Safety shut-off on pilot flame failure

- Pilot outlet flow adjustment

- Burner outlet pressure adjustment

- Outlet Pressure Adjustment Range:

  ‧NG 2"~5" W.C.

  ‧LPG 9"~12" W.C.

- Maximum Inlet Pressure: 35 mbar

- Flow Capacity (1" W.C. Pressure Drop):

  40,000 BTU/hr

- Operating Temperature: -23°C~80°C

- CV 970AM: ON-OFF operation

- CV 970AA: Solenoid operated pilot

  valve and burner valve by normal

  control or through remote handset for

  flame ignition